STARTING AND STOPPING
THE HONDA ENGINE
STARTING THE HONDA ENGINE
The Honda engine is equipped with a 110 volt AC starter.
1) Install tank.
2) Attach propane hose coupling and fully tighten.
3) Tilt machine back so that pad is off the floor.
4) Open propane tank valve (turn counterclockwise). Hose will fill.
Must not be any leaks.
5) Put throttle cable into the “fast” position.
6) Hook cord to starter connection and plug into wall outlet.
7) Push red start button and hold until the engine starts. Do not
crank for more than 20 seconds at a time and wait at least one
minute between tries when cranking. See troubleshooting guide if
the engine does not start after several tries.
8) After engine starts, unplug cord and return to storage position on
handle.
9) Set throttle to a slow operating speed until the motor warms up.
Can increase engine speed after 3 to 5 minutes.
STOPPING THE HONDA ENGINE
1) Turn propane tank valve to the closed position (turn clockwise)
and allow the engine to continue running until it runs out of fuel.
BETCO, CORP. 7/26/07 Page 10 PROPANE BURNISHER